A zone that will not start may have a connection problem between the timer and valve. We troubleshoot irrigation control wiring alongside the controller and solenoid so you do not replace working parts unnecessarily.
Sprinkler Master Repair (South Valley) • South Salt Lake County, Utah
Call (801) 988-9671Common symptoms
- Several stations stop responding together.
- One zone works intermittently.
- An error appears after digging, landscaping or valve work.
Station wire and common wire explained
On conventional multiwire systems, each station has its own control connection and valves often share a common return wire. Hunter’s testing guidance describes these connections. A technician compares the signal at the controller and valve to help locate where operation breaks down.
Watch: a valve will not turn on
This video from Hunter Landscape Irrigation explains troubleshooting a valve that does not start. Use it to understand the checks and describe the problem; follow the manual for your own equipment.
Watch the Hunter video on YouTube. Prefer written instructions? Read Hunter’s controller and solenoid testing guide. Hunter recommends a trained professional perform energized tests.
What we check
We review the error, affected zones and accessible wire connections before recommending a repair. Tell us about recent fence posts, planting or excavation. We also check whether the symptoms point to the controller, valve or water supply instead of wiring.
Leave energized testing to a trained professional. Household electrical supply work is different from irrigation control-wire troubleshooting; tell us if there is exposed mains wiring or damage to the controller’s power connection.

What to expect when scheduling
Read the exact error message and note which stations still work. Have the controller accessible, but do not disconnect or rearrange wires before the visit. Ask about the troubleshooting scope and price.
Sprinkler wiring questions—with practical answers
Several zones stopped working. Is the common wire broken?
A failed shared connection is one place to check before replacing several solenoids. In a conventional multiwire system, each station has a control wire and several valves share the common return. A loose or corroded common connection can interrupt more than one valve circuit.
First note which stations fail and which still run. If every zone is off, also check controller settings, a sensor hold, the irrigation water supply and any master valve. Hunter’s X-Core guide specifically includes common connections, master-valve connections and water supply. The failed-zone pattern directs testing; it is not proof that a buried wire is cut.
How do you tell a broken wire from a controller problem?
Compare the controller’s station output with the signal arriving at the valve while that station is commanded on. Output present at the controller but absent at the valve points toward a cut, disconnected or faulty field connection. No output at the controller calls for checking its settings, sensor status and station output before digging.
Hunter’s Pro-C troubleshooting sequence follows this controller-to-valve comparison. Its stated controller test range is 24–29 VAC. That is guidance for the equipment described, not a universal specification for battery-operated, DC-latching or two-wire decoder systems. Use the exact model’s manual.
These are technician tests. A controller cabinet can contain household-voltage wiring as well as low-voltage station terminals; do not probe an unfamiliar cabinet.
The timer shows watering, but the sprinklers are dry. What should I check first?
The watering icon shows a command, not confirmed water flow. Check whether the correct station has a run time, whether a sensor or rain delay is stopping watering, and whether the irrigation water supply is available. Record any error message before changing settings.
If the supply is available but the zone does not run, the next checks are the master valve, station connections and valve response. Hunter explains this symptom for X-Core controllers. Do not replace the timer solely because its display and the yard disagree. See our controller troubleshooting page.
Can I use an ordinary indoor wire nut in the valve box?
Use a connector rated for the actual irrigation wiring environment. Hunter specifies waterproof connectors for splices between the valve-control cable and solenoid leads. An ordinary indoor connector does not provide that specified water protection.
Match the connector’s permitted wire sizes and number of conductors, and follow its preparation instructions. Replacing the connector alone will not fix damaged cable farther along the run. See Hunter’s valve-service tools and splice guidance. Leave disconnecting and testing wiring to a trained professional when you are unsure how the system is powered.
Does a clicking solenoid prove the wiring is good?
No. A sound does not tell you what voltage reaches the valve or whether water can pass through it. A technician checks the electrical supply and the valve’s hydraulic operation separately. Hunter’s conventional AC test procedure measures between the station and common connections while the station is active; it specifies 24–28 VAC at the solenoid for the setup described.
Read Hunter’s voltage-testing guidance. A valve can also fail to open because its internal passages are blocked, so voltage alone does not establish the whole diagnosis. See Hunter’s valve-not-opening checklist and our solenoid repair guide.
Where to buy sprinkler wiring parts locally
These are independent retailers, not Sprinkler Master service locations. Call the store to confirm current hours, stock and return terms before visiting.
- Sprinkler Supply Company — West Jordan
7878 S 1410 W, West Jordan, UT 84088. Official store directory. - Sprinkler Supply Company — Riverton
11654 S Redwood Rd, Riverton, UT 84095. Official store directory. - Sprinkler World — Sandy
Official Sandy store listing. Confirm the location and parts availability directly.
Bring the controller and connector details
Bring a photo of the controller model label and readable cable markings. Ask for connectors rated for the installation environment and the actual wire sizes and conductor count. Do not disconnect wiring just to bring a sample.
Supplier listings checked October 6, 2026. Specific fitting and repair-kit stock has not been confirmed.
Detailed answers to related sprinkler problems
Get professional sprinkler wiring help
We check the affected station and common connections, narrow down the electrical fault, and explain the repair. Afterward, we test whether the valve responds from the controller.
A systematic diagnosis can save time replacing several solenoids when a shared connection is the problem.
Sprinkler Master Repair (South Valley)
Call with your city, the affected zone and what the sprinklers are doing. We’ll confirm availability and explain the next step.
Need another Sprinkler Master location?
For a property outside this area, use the Sprinkler Master location directory. Each location has its own service area and contact details.
Towns and communities we serve
Explore our local service pages below. Call (801) 988-9671 to confirm availability for your address.
- Cottonwood Heights, UT
- Bluffdale UT
- Draper Utah
- Herriman UT
- Holladay UT
- Kearns UT
- Magna UT
- Midvale, UT
- Millcreek UT
- Murray UT
- Riverton UT
- Sandy Utah
- South Jordan Utah
- Taylorsville UT
- West Jordan Utah
- West Valley City UT
- White City Utah
Outside Salt Lake County? Our Tooele service page has information for that area; call to confirm coverage and travel arrangements.
Wiring diagnostic diagrams
These guides explain the troubleshooting sequence. Energized measurements and wiring repairs should be handled by a trained professional.
Zone will not start: choose the next check
- Record the station number, error message and whether other zones work.
- All zones affected → Check program, sensor status, water supply and master-valve operation. One zone affected → Focus on that station’s circuit and valve.
- Technician checks controller output and then the signal at the valve → A missing signal at the valve directs attention to the field wire and connections.
- Correct model-specific signal reaches the valve → Check the solenoid and valve operation instead of automatically replacing the controller.
Several zones fail together
- List the working and failed stations.
- Check shared common connections and any master-valve circuit.
- Confirm water supply and controller settings before deciding a cable or multiple solenoids have failed.
Controller or field wiring?
- Technician activates the affected station and checks its output.
- Output at controller but missing at valve → Trace the field circuit and splices.
- No output at controller → Check settings, sensor state and station output before excavation.
Watering icon but no water
- Confirm the intended station and run time; record active holds and errors.
- Confirm irrigation supply availability and any master-valve issue.
- Supply available but zone still dry → Arrange station-circuit and valve testing.
Choosing a valve-box connector
- Read the connector’s environment, wire-size and conductor-count ratings.
- Use a suitable waterproof irrigation splice connector and its installation instructions.
- Damaged cable or uncertain power isolation → Have the wiring repaired and tested professionally.
Solenoid clicks but zone stays dry
- Do not treat the click as proof of correct voltage or water flow.
- Technician compares the measured supply with the equipment specifications.
- Check valve passages and hydraulic operation as well as the electrical circuit.
Sources: Hunter Pro-C troubleshooting · Hunter X-Core checks · Waterproof splice guidance.